RUS
lists three basic types of signs: warning,
cable route, and buried splice location.
In addition to the requirements shown
under the general listing procedures,
the following information is required
in a request for RUS product acceptance
cable markers and mounting posts:
A.
Requirements for Signs
1.
Warning Sign
a.
Vertical 4 x 12 inch plate metal of 0.40
inch thick 6000 series aluminum or other
material acceptable to RUS.
b.
Black lettering printed by silk screening
on an orange background to a 2 mil thickness
with a baked protective coating.
c.
Hardware for mounting the sign to the
signpost shall be 6000 series aluminum
or 300 series stainless steel. Other materials
may be substituted for the above materials
provided the materials are acceptable
to RUS.
2.
Cable Route Sign
a.
Horizontal 4 x 12 inch plate metal of
0.040 inch thick 6000 series aluminum
plate or other material acceptable to
RUS.
b.
Black lettering printed by silk screening
on an orange background to a 2 mil thickness
with a baked protective coating.
c.
Hardware for mounting the sign to the
signpost shall be 6000 series aluminum
or 300 series stainless steel. Other materials
may be substituted for the above materials
provided the materials are acceptable
to RUS.
3.
Cable Splice Location Sign
a.
Vertical 4 x 12 inch plate metal of 0.40
inch thick 6000 series aluminum or other
material acceptable to RUS.
b.
Black lettering printed by silk screening
on an orange background to a 2 mil thickness
with a baked protective coating.
c.
Hardware for mounting the sign to the
signpost shall be 6000 series aluminum
or 300 series stainless steel. Other materials
may be substituted for the above materials
provided the materials are acceptable
to RUS.
B.
Requirements for a Post/Sign Combination
1.
Materials for the mounting posts shall
be 12 gauge galvanized steel or other
materials acceptable to RUS.
2.
Colors for the mounting posts shall be
gray-green, green, or orange having a
baked finished
3.
Length shall be 8 feet.
4.
Samples of the mounting post/sign combination.
5.
Engineering drawings of the mounting post/sign
combination.
6.
Catalog designation of the mounting post/sign
combination.
C.
Requirements for Mounting Post Only
1.
Materials for the posts shall be 12 gauge
galvanized steel or other materials acceptable
to RUS.
2.
Colors for the posts shall be gray-green,
green, or orange having a baked finished
3.
Length shall be 8 feet.
4.
Samples of the post.
5.
Engineering drawings of the mounting post.
6.
Catalog designation of the mounting post
For
further information or clarification on
the above acceptance procedures, please
contact:
Norberto
Esteves
norberto.esteves@usda.gov
|