Telecommunications Program

Section 5
- Electrical Protective Devices - ni Protectors

RDUP Acceptance Procedures for Building Entrance Terminal (BET), Protected
 

 

Item ni

In addition to the requirements shown under the general listing procedures, the following information is required in a request for initial acceptance of building entrance terminals (BET), Protected.

Product Description

The application should describe the type of protection included with the protected building entrance terminal (BET) such as carbon, gas tube, or solid-state surge arresters units.

Catalog designations for each BET according to pair size must be included in the application.

A product bulletin and an installation procedure concerning the BET must be included in the application.

Conformance to Standards

Test data indicating that the protected BET either conforms to Telcordia Technical Reference TR-NWT-000937, January 1993, "Generic Requirements for Building Entrance Terminals," or some other recognized industry standard for BET units.

A certification that the BET is listed for the purpose in accordance with the National Electrical Code (NEC) when tested for the purpose by a recognized testing laboratory must be included in the application. These certifications shall be accomplished by the submission photocopies of the reports and letters of approval of such laboratories.

If the BET uses carbon arresters, test data indicating that the carbon arrester units either comply with the "Station Protection" requirements specified in RUS Bulletin 345-78, "RUS Specification for Carbon Arrester Assemblies for Use in Protectors, PE-78," or a certification indicating that the carbon arrester units are currently RUS accepted.

If the BET uses gas tube arresters, test data indicating that the gas tube arrester units either comply with the RUS Acceptance Procedures for Gas Tube Arresters - Item Designation "nh-a" or a certification indicating that the gas tube arrester units are currently RUS accepted. Indicate the duty class (light, medium, heavy, or maximum duty) of the gas tube surge arresters your company intends to use with the BET. The RUS Acceptance Procedures for Gas Tube Arresters (Item Designation "nh-a") can be found at the following web address: http://www.usda.gov/rus/telecom/listing procedures/section 5/nh lop.htm
If the BET uses solid-state surge arresters, test data indicating that the solid-state surge arrester units either comply with the RUS Acceptance Procedures for Solid-State Surge Arresters - Item Designation "nh-b" or a certification indicating that the solid-state surge arrester units are currently RUS accepted. The RUS Acceptance Procedures for Solid-State Surge Arresters (Item Designation "nh-b") can be found at the following web address: http://www.usda.gov/rus/telecom/listing procedures/section 5/nh lop.htm

Samples

The manufacturer shall submit one 12-pair BET fully equipped with protection and cover.

For further information or clarification on the above acceptance procedures, please contact: